Do you know how to maintain the air shower room?
1. Pre-filter (PRE-FILTER): The pre-filter is below the device. The pre-filter can be easily pulled out by removing the circulating air return vent. The blockage of the pre-filter depends on the frequency of use and the clean state. Please observe the blockage time in the early stage of use, and then clean it regularly with compressed air, water washing, and vacuum cleaning. It is necessary to clean 2-3 times a month according to normal usage.
2. Main filter (MAIN FILTER) This filter is located after AIR NOZZLE, and its update period can be determined according to the wind speed value detected by the anemometer (the wind value is halved) or the pressure difference measured by the differential pressure meter (the differential pressure value is doubled). No, the inspection cycle is about two to four times a year.
3. Due to the internal circulation and return air part of the equipment, which is located under the machine, there will be large contaminants accumulated in the corners on the bottom plate, so please clean it with a vacuum cleaner more than once a week. Make sure that the blower rotates in the correct direction. If it is found that the fan rotates in the opposite direction (the wind speed is obviously insufficient), please exchange any 2-phase power lines of the three-phase power supply to make sure that it rotates in the positive direction.